IMMOBILIZER (DIAGNOSTICS) > Clear Memory Mode

OPERATION

1. On the «Main Menu» display screen, select {Each System Check} and press the [YES] key.

2. On the «System Selection Menu» display screen, select {Engine Control System} and press the [YES] key.

3. Press the [YES] key after the information of engine type is displayed.

4. On the «Engine Diagnosis» display screen, select the {Clear Memory} and press the [YES] key.

5. When “Done” is shown on the display screen, turn the Subaru Select Monitor and ignition switch to OFF.

NOTE:

After the memory has been cleared, the idle air control solenoid valve must be initialized. To execute this procedure, turn the ignition switch to ON. Wait for 3 seconds before starting the engine.

For detailed operation procedure, refer to the “SUBARU SELECT MONITOR OPERATION MANUAL”.