1.CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE LH CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from the ECM and secondary air combination valve LH.
3) Measure the resistance of the harness between the ECM and secondary air combination valve relay LH connector terminal.
Connector & terminal
(B134) No. 27 — (E41) No. 2:
(B134) No. 19 — (E41) No. 1:
(B134) No. 29 — (E41) No. 3:
|
Is the resistance less than 1 Ω?
|
|
Repair open circuit of the harness between the ECM and secondary air combination valve relay LH connector.
|
2.CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE LH CONNECTOR.
Measure the voltage between ECM and chassis ground.
Connector & terminal
(B134) No. 27 (+) — Chassis ground (−):
|
Is the voltage 5 V or more?
|
Repair the short to power supply in the harness between the ECM and secondary air combination valve relay LH connector.
|
Temporary poor contact occurs. Check the poor contact of connector.
|