FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Fuel Delivery and Evaporation Lines

INSTALLATION

1. Connect the quick connector on fuel line.

CAUTION:

Make sure that the connected portion is not damaged and is free of dust and contamination. If necessary, clean seal surface of pipe.

NOTE:

Use a new retainer.

(A)

Seal surface

(B)

Pipe

(1) Set the new retainer (B) to connector (A).

(2) Push the pipe into the connector completely.

(A)

Connector

(B)

Retainer

(C)

Pipe

CAUTION:

Pull the connector to ensure it is connected securely.

Make sure the two retainer claws are engaged in their mating positions in the connector.

Be sure to inspect hoses and their connections for any leakage of fuel.

(A)

Connector

(B)

Retainer

(C)

Pipe

2. Connect the fuel delivery hose to the pipe with an overlap of 20 to 25 mm (0.79 to 0.98 in).

Type A: When the amount to be inserted is specified.

Type B: When the amount to be inserted is not specified.

L: 2.5±1.5 mm (0.098±0.059 in)

L: 22.5±2.5 mm (0.886±0.098 in)

CAUTION:

Be sure to inspect hoses and their connections for any leakage of fuel.

(1)

Type A

(2)

Type B

(3)

Pipe

(4)

Clamp

(5)

Hose

3. Connect the evaporation hose to the pipe with an overlap of 15 to 20 mm (0.59 to 0.79 in).

L = 17.5±2.5 mm (0.689±0.098 in)

(1)

Hose

(2)

Clip

(3)