HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Compressor

INSPECTION

1. MAGNETIC CLUTCH CLEARANCE

Check the clearance of the entire circumference around the drive plate and pulley.

Standard:

0.3 — 0.6 mm (0.0118 — 0.0236 in)

2. MAGNETIC CLUTCH OPERATION

1. Disconnect the compressor connector.

2. Connect the battery positive (+) terminal to the terminal No. 3 of the compressor connector.

3. Confirm the magnet clutch engagement.

If there is a problem, replace the compressor.