CHECK INPUT SIGNAL FOR ECM (USING SUBARU SELECT MONITOR).

Read the data of atmospheric absolute pressure signal using Subaru Select Monitor.

NOTE:

For detailed operation procedure, refer to “READ CURRENT DATA FOR ENGINE”.

QUESTION

Is the measured value 13.3 kPa (100 mmHg, 3.94 inHg) or more when shaking the ECM harness and connector?

Yes No

Repair the poor contact of ECM connector.