| CHECK CURRENT DATA. |
|
1) Start the engine. 2) Read the data of tumble generator valve position sensor signal using Subaru Select Monitor or general scan tool. NOTE: |
| QUESTION | |
|
Is the voltage less than 0.1 V? | |
| Yes | No |
|
Even if the malfunction indicator light illuminates, the circuit has returned to a normal condition at this time. Temporary poor contact of connector may be the cause. NOTE: In this case, repair the following item: • Poor contact of tumble generator valve position sensor connector • Poor contact in ECM connector • Poor contact of coupling connector |
|