Measure the resistance of harness between ECM and main fan relay connector.
Connector & terminal
(B135) No. 19 — (F27) No. 32:
Is the resistance less than 1 Ω?
Repair the harness and connector.
NOTE:
In this case, repair the following item:
• Open circuit of harness between ECM and main fan relay connector
• Poor contact of coupling connector