CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY.

Measure the voltage between ECM and chassis ground.

Connector & terminal

(B135) No. 34 (+) — Chassis ground:

QUESTION

Is the voltage 10 V or more?

Yes No

Repair power supply short circuit of the harness between ECM and secondary air combination valve relay.

Temporary poor contact occurs. Check the poor contact of connector.