CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE LH CONNECTOR.

Measure the voltage between ECM and chassis ground.

Connector & terminal

(B136) No. 7 (+) — Chassis ground (−):

QUESTION

Is the voltage 5 V or more?

Yes No

Repair the short to power supply in the harness between the ECM and secondary air combination valve relay LH connector.

Temporary poor contact occurs. Check the poor contact of connector.