CHECK G SENSOR.

Measure the voltage between G sensor connector terminals.

Connector & terminal

(B292) No. 2 (+) — No. 3 (−)

QUESTION

Is the voltage 0.7±0.2 V when the G sensor is inclined backward 90°?

Yes No

G sensor is normal.

Replace the G sensor.