CHECK HARNESS BETWEEN AT SHIFT LOCK CONTROL MODULE AND KEY LOCK SOLENOID.

Measure the resistance of the harness between the AT shift lock control unit and chassis ground.

Connector & terminal

LHD model

(B373) No. 9 — Chassis ground:

RHD model

(B376) No. 9 — Chassis ground:

QUESTION

Is the resistance 1 Ω or more?

Yes No

Repair short circuit of the harness between AT shift lock control module and key lock solenoid.