CHECK HARNESS BETWEEN FUEL SUB LEVEL SENSOR AND COMBINATION METER.

1) Disconnect the connector from the combination meter.

2) Measure the resistance between the fuel sub level sensor harness connector terminal and combination meter harness connector terminal.

Connector & terminal

(R59) No. 1 — (i11) No. 1:

QUESTION

Is the resistance less than 10 Ω?

Yes No

Repair the wiring harness.