CHECK OUTPUT SIGNAL.

Measure the voltage between the keyless entry control module harness connector terminal and the chassis ground when the LOCK button of the keyless transmitter is pressed.

Connector & terminal

(B176) No. 18 (+) — Chassis ground (−):

QUESTION

Is the voltage 10 V or more?

Yes No

Replace the double lock unit.

Check the harness for open circuits or shorts between the keyless entry control module and the double lock unit.