CHECK DOOR LOCK SWITCH CIRCUIT.

1) Disconnect the keyless entry control module or double lock unit harness connector.

2) Measure the resistance between the harness connector terminal and chassis ground when moving the door lock switch to LOCK.

Connector & terminal

Model without double lock:

(B176) No. 10 — Chassis ground:

Model with double lock:

(B325) No. 7 — Chassis ground:

QUESTION

Is the resistance less than 10 Ω?

Yes No