KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM (DIAGNOSTICS) > Read Current Data
(1) Collation CM
|
Items to be displayed |
Unit of measure |
Content |
Note |
|
Driver’s Request SW |
ON/OFF |
Collation CM input value |
ON when the driver’s door lock/unlock button is pressed |
|
Passenger’s Request SW |
ON/OFF |
Collation CM input value |
ON when the passenger’s door lock/ unlock button is pressed |
|
Rear Gate Request SW |
ON/OFF |
Collation CM input value |
ON when rear lock button is pressed |
|
IGN SW |
ON/OFF |
Collation CM input value |
ON when ignition is ON |
|
ACC SW |
ON/OFF |
Collation CM input value |
ON when accessory or ignition is ON |
|
Incorrect vehicle ID |
Yes/No |
Collation CM internal value |
Yes when the access key is different when keyless access is performed |
|
No response |
Yes/No |
Collation CM internal value |
Yes when there is no response from the access key when keyless access is performed |
|
Incorrect response code, format |
Yes/No |
Collation CM internal value |
Yes if the response from the access key differs when keyless access is performed |
|
Exhausted battery |
Yes/No |
Collation CM internal value |
Yes if the access key battery is depleted |
|
Incorrect response code, ID code |
Yes/No |
Collation CM internal value |
Yes if the response from the access key differs when keyless access is performed |
|
Incorrect response code, collation result |
Yes/No |
Collation CM internal value |
Yes if the response from the access key differs when keyless access is performed |
|
Incorrect ID code |
Yes/No |
Collation CM internal value |
Yes if the response from the access key differs when keyless access is performed |
|
Incorrect rolling code |
Yes/No |
Collation CM internal value |
Yes if the response from the access key differs when keyless access is performed |
|
Smart Cancel |
Cancel/Normal |
Collation CM internal value |
Cancel in the keyless access function stopped condition |
|
Immobirizer |
Unset/Set |
Collation CM internal value |
Unset with ignition ON, etc. |
|
ECM intercommunication ID confirmation |
OK/NG |
Collation CM internal value |
ID collation matches, OK |
|
Code registration confirmation |
Registered/Unregistered |
Collation CM internal value |
Registered with code registration |
|
Abnormal EEPROM access |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
IGN1 (linear) status |
ON/OFF |
Collation CM input |
ON when ignition ON |
|
IGN1 (communication) |
ON/OFF |
Collation CM input |
ON when ignition ON |
|
Lock confirmation |
Confirmed/Not confirmed |
Steering lock CM internal value |
Confirmed when steering lock is locked |
|
Unlock confirmation |
Confirmed/Not confirmed |
Steering lock CM internal value |
Confirmed when steering lock is unlocked |
|
Engine start |
Engine start permission/Engine start prohibition |
Steering lock CM internal value |
Permission when ignition ON |
|
Sensor abnormal (past) |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
Motor power supply short-circuit abnormal (past) |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
Motor power supply open abnormal (past) |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
Motor driver short-circuit abnormal (past) |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
Motor driver open abnormal (past) |
Abnormal/Normal |
Steering lock CM internal value |
Abnormal when a trouble occurs in steering lock CM |
|
Steering lock lock/unlock command reception history |
ON/OFF |
Steering lock CM internal value |
ON when steering lock is locked → unlocked, unlocked → locked |
|
Lock bar engagement abnormal (past) |
ON/OFF |
Steering lock CM internal value |
ON when the steering lock bar has experienced interference in the past |
|
Push start abnormal (past) |
Abnormal/Normal |
Push button start function trouble |
Abnormal when a trouble occurs in steering lock CM |
|
Sleep possible status |
Possible/Impossible |
ID code box internal value |
|
|
Wake-up transmission status |
Transmission/No transmission |
ID code box internal value |
|
|
EGI code reception status |
Not yet received/Reception |
ID code box internal value |
Reception at engine start operation |
|
Engine start permission request reception status |
Not yet received/Reception |
ID code box internal value |
Reception at ignition ON |
|
Provisional injection request reception status |
Not yet received/Reception |
ID code box internal value |
Reception at ignition ON |
|
Code collation result between collated ECM and ID code box |
Abnormal/Normal |
ID code box internal value |
Normal when engine start is allowed |
|
Code collation result between steering locked ECM and ID code box |
Abnormal/Normal |
ID code box internal value |
Normal when steering lock operation allowed |
|
Steering lock unlock request reception status |
Not yet received/Reception |
ID code box internal value |
Reception when steering lock is performing unlock |
|
Steering lock lock request reception status |
Not yet received/Reception |
ID code box internal value |
Reception when steering lock is performing lock |
|
ID code registration mode status |
Normal/Regist./Deletion |
— |
For immobilizer registration |
|
Smart related ECM code registration mode status |
On mode/Normal | ||
|
ID code collation completion confirmation |
Completed/Normal | ||
|
Smart related ECM code confirmation status |
Completed/Normal | ||
|
ID code registration status |
Registering/Normal | ||
|
ID code registration completion confirmation |
Completed/Normal | ||
|
ID code collation status |
Normal/Collating the immobilizer/Collating the smart | ||
|
All registered keys confirmation status |
Confirming/Normal | ||
|
Confirmed number of all registered keys |
0 — 7 | ||
|
Number of required registrations (smart) |
0 — 7 | ||
|
Number of collation completed (smart) |
0 — 7 | ||
|
Number of registration completed (smart) |
0 — 7 |
Collation CM internal value |
|
|
ID Code Box |
Connecting/Not connected |
Collation CM internal value |
Connecting with ID code box normal connection |
|
Power Supply ECM |
Connecting/Not connected |
Collation CM internal value |
Connecting with power supply CM normal connection |
|
Steering Lock ECM |
Connecting/Not connected |
Collation CM internal value |
Connecting with steering lock CM normal connection |
|
Driver’s request SW ON edge history |
ON/OFF |
Collation CM internal value |
ON when verified with the combination shown on the left. (Once it becomes “ON”, the display is maintained.) NOTE: |
|
Passenger’s request SW ON edge history |
ON/OFF |
Collation CM internal value | |
|
Rear gate request SW ON edge history |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (driver’s external transmitter + interior tuner) |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (passenger’s external transmitter + interior tuner) |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (front interior transmitter + interior tuner) |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (rear gate internal transmitter + interior tuner) |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (rear gate external transmitter + interior tuner) |
ON/OFF |
Collation CM internal value | |
|
Collation OK result history (immobilizer amplifier + immobilizer amplifier) |
ON/OFF |
Collation CM internal value |
(2) Power supply CM
|
Items to be displayed |
Unit of measure |
Content |
Note |
|
Push start SW 1 |
ON/OFF |
Input value |
ON when push button start is pressed |
|
Push start SW 2 |
ON/OFF |
Input value |
ON when push button start is pressed |
|
Stop lamp SW |
ON/OFF |
Input value |
ON when brake pedal is depressed |
|
Steering unlock SW |
ON/OFF |
Input value |
OFF when steering locked |
|
Shift P signal |
ON/OFF |
Input value |
ON when the shift position is P |
|
Neutral SW/Clutch SW |
ON/OFF |
Output value |
ON when the shift position is at “P” or “N” |
|
IGN2 relay monitor (drive output) |
ON/OFF |
Output value |
ON during IG relay 2 (push button start) drive output |
|
IGN1 relay monitor (drive output) |
ON/OFF |
Output value |
ON during IG relay 1 (push button start) drive output |
|
ACC relay monitor |
ON/OFF |
Output value |
ON during accessory relay (push button start) drive output |
|
IGN2 relay monitor (coil voltage) |
ON/OFF |
Output value |
ON during IG relay 2 (push button start) drive output |
|
IGN1 relay monitor (coil voltage) |
ON/OFF |
ON during IG relay 1 (push button start) drive output |
ON during IG relay 1 (push button start) drive output |
|
IGN latch monitor |
ON/OFF |
Output value |
ON during IG relay 2 (push button start) drive output |
|
STSW signal monitor |
ON/OFF |
Output value |
ON when brake pedal is depressed, and push button ignition switch is pressed |
|
ACCR signal |
ON/OFF |
Input value |
ON during starter relay drive output |
|
Vehicle speed signal |
Drive status/Stop status |
Input value |
Drive status when vehicle speed is input |
|
Engine Speed |
Rotating/Stopped |
Input value |
Rotating when engine driven |
|
Power supply status |
All OFF status |
Output value |
Displayed when IG relay 1 (push button start), IG relay 2 (push button start), and accessory relay (push button start) are all OFF |
|
ACC relay ON status |
Output value |
Displayed when accessory ON | |
|
IGN1 relay ON status |
Output value |
Displayed when ignition ON | |
|
IGN2 relay ON status |
Output value |
Displayed when ignition ON | |
|
STSW Condition |
Output value |
Displayed when push button ignition switch is pressed without depressing the brake pedal |
(3) Body integrated unit
Refer to READ CURRENT DATA of the LAN system 
(4) Gateway CM
|
Items to be displayed |
Unit of measure |
Content |
Note |
|
BD_Wake line status |
Wakeup/Sleep |
Gateway input value |
Wakeup when keyless access system wake up due to door open/close operation |
|
Direct line IGN entry status |
ON/OFF |
Gateway input value |
ON when ignition ON |
|
Direct line ACC entry status |
ON/OFF |
Gateway input value |
ON with the accessory condition |