1.CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY.
1) Turn the ignition switch to OFF.
2) Disconnect the connector from the ECM and secondary air combination valve relay.
3) Measure the resistance of the harness between ECM and secondary air combination valve relay.
Connector & terminal
(B135) No. 15 — (F9) No. 2:
|
Is the resistance less than 1 Ω?
|
|
Repair open circuit of the harness between ECM and secondary air combination valve relay.
|
2.CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY.
Measure the resistance between ECM and chassis ground.
Connector & terminal
(B135) No. 15 — Chassis ground:
|
Is the resistance 1 MΩ or more?
|
Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the fault condition, and reperform the check.
NOTE:
In this case, there may be a temporary connector contact failure.
|
Repair ground short circuit of the harness between ECM and secondary air combination valve relay.
|