FUEL INJECTION (FUEL SYSTEMS)(H4DOTC) > Oil Flow Control Solenoid Valve

ASSEMBLY

1. Install the oil flow control solenoid valve.

Tightening torque:

8 N·m (0.8 kgf-m, 5.9 ft-lb)

2. Apply liquid gasket to the two bolts which secure the oil return cover.

Liquid gasket:

THREE BOND 1324 (Part No. 004403042) or equivalent

3. Attach the oil return cover and gasket.

Tightening torque:

8 N·m (0.8 kgf-m, 5.9 ft-lb)

NOTE:

Use a new gasket.

(A)

Oil flow control solenoid valve

(B)

Oil return cover

(C)

Gasket

(D)

Camshaft cap