FUEL INJECTION (FUEL SYSTEMS)(H4DOTC) > Oil Flow Control Solenoid Valve
1. Install the oil flow control solenoid valve.
Tightening torque:
8 N·m (0.8 kgf-m, 5.9 ft-lb)
2. Apply liquid gasket to the two bolts which secure the oil return cover.
Liquid gasket:
THREE BOND 1324 (Part No. 004403042) or equivalent
3. Attach the oil return cover and gasket.
Tightening torque:
8 N·m (0.8 kgf-m, 5.9 ft-lb)
NOTE:
Use a new gasket.
|
(A) |
Oil flow control solenoid valve |
|
(B) |
Oil return cover |
|
(C) |
Gasket |
|
(D) |
Camshaft cap |