EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)(H4DO) > Canister

INSTALLATION

Install in the reverse order of removal while being careful of the following.

Connect the quick connector as shown in the figure.

CAUTION:

Check that there is no damage or dust on the quick connector. If necessary, clean seal surface of pipe.

When connecting the quick connector, insert the pipe all the way in securely, then operate the push lock.

If it is not possible to perform the push lock operation of the retainer, recheck whether the pipe is securely inserted.

Confirm that the quick connector is securely connected.

(a)

Retainer

Tightening torque:

18 N·m (1.8 kgf-m, 13.3 ft-lb)

Tightening torque:

8 N·m (0.8 kgf-m, 5.9 ft-lb)

Tightening torque:

18 N·m (1.8 kgf-m, 13.3 ft-lb)