SECURITY AND LOCKS > IG Relay 2 (Push Button Start)

INSPECTION

Measure the resistance between the IG relay 2 (push button start) terminals when connecting terminal No. 4 to the battery positive terminal and terminal No. 3 to the battery ground terminal.

Continuity

Terminal No.

Standard

Yes

1 and 2

Less than 1 Ω

None

1 MΩ or more

NOTE:

Replace IG relay 2 (push button start) if faulty.