LIGHTING SYSTEM > Room Light

INSPECTION

1. ROOM LIGHT BULB

1. Visually check the bulb for blow out.

2. Check the bulb specification.

3. If NG, replace the bulb with a new part.

2. ROOM LIGHT SWITCH

1. Measure the resistance between room light switch terminals.

(A)

Model without sunroof

(B)

Model with sunroof

Switch position

Terminal No.

Standard

OFF

1 MΩ or more

ON

1 and 3

1.5±0.5 Ω

Door

2 and 3: Model without sunroof

1 and 2: Model with sunroof

1.5±0.5 Ω

2. Check the room light illumination condition.

Model without sunroof

Connect terminal No. 3 to the battery positive terminal and terminal No. 1 and No. 2 to the battery ground terminal.

Model with sunroof

Connect terminal No. 1 to the battery positive terminal and terminal No. 2 and No. 3 to the battery ground terminal.

Switch position

Light status

OFF

Light OFF

ON

Light ON

Door

Light ON

3. Replace the room light if faulty.