LIGHTING SYSTEM > Combination Switch (Light)
Measure the resistance between combination switch terminals.
|
(A) |
Except for KA model |
|
(B) |
KA model |
• KA model
|
Switch position |
Terminal No. |
Standard |
|
OFF |
— |
1 MΩ or more |
|
Tail |
15 and 9 |
Less than 1 Ω |
|
Head |
14, 15 and 9 |
Less than 1 Ω |
• Except for KA model
|
Switch position |
Terminal No. |
Standard |
|
OFF |
— |
1 MΩ or more |
|
Tail |
14 and 16 |
Less than 1 Ω |
|
Head |
13, 14 and 16 |
Less than 1 Ω |
Replace the combination switch (light) if faulty.
• KA model
|
Switch position |
Terminal No. |
Standard |
|
Passing |
1, 2 and 9 |
Less than 1 Ω |
|
High beam |
2 and 9 |
Less than 1 Ω |
• Except for KA model
|
Switch position |
Terminal No. |
Standard |
|
Passing |
7, 8 and 16 |
Less than 1 Ω |
|
High beam |
7 and 16 |
Less than 1 Ω |
Replace the combination switch (light) if faulty.
• KA model
|
Switch position |
Terminal No. |
Standard |
|
Left |
6 and 7 |
Less than 1 Ω |
|
Neutral |
— |
1 MΩ or more |
|
Right |
7 and 8 |
Less than 1 Ω |
• Except for KA model
|
Switch position |
Terminal No. |
Standard |
|
Left |
1 and 2 |
Less than 1 Ω |
|
Neutral |
— |
1 MΩ or more |
|
Right |
2 and 3 |
Less than 1 Ω |
Replace the combination switch (light) if faulty.
• KA model
|
Switch position |
Terminal No. |
Standard |
|
OFF |
12 and 16 |
1 MΩ or more |
|
ON |
Less than 1 Ω |
• Except for KA model
|
Switch position |
Terminal No. |
Standard |
|
OFF |
10 and 11 |
1 MΩ or more |
|
ON |
Less than 1 Ω |
Replace the combination switch (light) if faulty.
|
Switch position |
Terminal No. |
Standard |
|
OFF |
10 and 12 |
1 MΩ or more |
|
ON |
Less than 1 Ω |
Replace the combination switch (light) if faulty.