LIGHTING SYSTEM > Room Light System

INSPECTION

1. DOOR SWITCH

Measure the resistance between door switch terminals.

Switch position

Terminal No.

Standard

When door is opened

1 and 3

Less than 1 Ω

When door is closed

1 MΩ or more

Replace the door switch if faulty.

2. REAR GATE LATCH SWITCH

Measure the resistance between rear gate latch switch terminals.

Switch position

Terminal No.

Standard

When rear gate is opened

3 and 4

Less than 1 Ω

When rear gate is closed

1 MΩ or more

Replace the rear gate latch and actuator assembly if faulty.