CHECK HARNESS.

Using the tester, measure the resistance between terminals of data link connector and yaw rate sensor.

Connector & terminal

(B40) No. 14 — (B230) No. 3:

(B40) No. 6 — (B230) No. 2:

QUESTION

Is the resistance less than 10 Ω?

Yes No

Replace the yaw rate sensor.