CHECK COLLATION CM.

1) Disconnect the collation CM connector.

2) Using a tester, measure the voltage between the collation CM connector and chassis ground.

Connector & terminal

(B421) No. 1 (+) — Chassis ground (−):

QUESTION

Is the voltage 10 V or more?

Yes No

Repair or replace the open circuit of harness.