CHECK HARNESS BETWEEN ECM AND WASTEGATE CONTROL SOLENOID VALVE.

1) Turn the ignition switch to OFF.

2) Disconnect the connectors from ECM and wastegate control solenoid valve.

3) Measure the resistance between wastegate control solenoid valve connector and engine ground.

Connector & terminal

(E64) No. 2 — Engine ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Repair ground short circuit of harness between ECM and wastegate control solenoid valve connector.