CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RH CONNECTOR.

Measure the resistance between ECM and chassis ground.

Connector & terminal

(B134) No. 27 — Chassis ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Repair the ground short circuit of harness between ECM and secondary air combination valve RH connector.