CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY CONNECTOR.

Measure the resistance between the secondary air combination valve relay connector and chassis ground.

Connector & terminal

(F9) No. 2 — Chassis ground:

QUESTION

Is the resistance 1 MΩ or more?

Yes No

Repair the poor contact of the ECM connector.

Repair the ground short circuit of harness between ECM and secondary air pump relay connector.