| CHECK POWER SUPPLY OF SUB FUEL PUMP RELAY. |
|
1) Turn the ignition switch to OFF. 2) Remove the sub fuel pump relay. 3) Disconnect the connector from ECM. 4) Turn the ignition switch to ON. 5) Measure the voltage between sub fuel pump relay connector and chassis ground. Connector & terminal LHD model with push button start (B220) No. 16 (+) — Chassis ground (−): Except for LHD model with push button start (B220) No. 15 (+) — Chassis ground (−): |