CHECK HARNESS BETWEEN ECM AND DPF PRESSURE DIFFERENTIAL SENSOR CONNECTOR.

Measure the voltage between ECM connector and chassis ground.

Connector & terminal

(B134) No. 56 (+) — Chassis ground (−):

(B134) No. 72 (+) — Chassis ground (−):

QUESTION

Is the voltage 5 V or more?

Yes No

Repair the short circuit to power supply in harness between ECM connector and DPF pressure difference sensor connector.