| CHECK INPUT VOLTAGE OF STARTER RELAY. |
|
1) Turn the ignition switch to OFF. 2) Remove the starter relay. 3) Connect the connector to ignition switch. 4) Measure the voltage between starter relay connector and chassis ground after turning the ignition switch to START position. Connector & terminal LHD model (B225) No. 9 (+) — Chassis ground (−): RHD model (B225) No. 24 (+) — Chassis ground (−): |