CHECK STARTER RELAY.

1) Connect the battery to starter relay terminals No. 11 and No. 12 (LHD model) or No. 22 and No. 23 (RHD model).

2) Measure the resistance between starter relay terminals.

Terminals

LHD model

No. 9 — No. 10:

RHD model

No. 24 — No. 25:

QUESTION

Is the resistance less than 1 Ω?

Yes No

Replace the starter relay.