1) Disconnect the connectors from the ECM.
2) Measure the resistance between the sub fan relay terminal and ECM connector.
Connector & terminal
(B136) No. 18 — (F27) No. 12:
Is the resistance less than 1 Ω?
Repair the open circuit of harness between sub fan relay terminal and ECM.